ScholarMatic | 24/7 Homework Help

ScholarMatic Will Help You Write Your Essays and Term Papers

Answered » You can buy a ready-made answer or pick a professional tutor to order an original one.

Consider the blending system shown in Figure. A feedback control

by | Nov 30, 2023 | questions

Consider the blending system shown in Figure. A feedback control system is used to reduce the effect of disturbances in feed composition, x1, n the controlled variable, product composition, x. Inlet flow rate, w2, can be manipulated. Do the following:
(a) Draw a block diagram of the feedback control system.
(b) Using the information shown below, derive a transfer function for each block.
(c) Simulate the closed-loop response for the given PI controller settings and a step disturbance of + 0.2 in x1.
(d) Repeat part (c) for a set-point change of – 0.1. Attempt to obtain belier closed-Loop responses by tuning the P1 controller. Which controller settings give the best results?
(e) Attempt to obtain improved control by adding derivative action to your best Pt controller of part (d). Try several values of derivative time, TD. Which one gives the best results?
(f) Suppose that the sampling line to (he composition analyzer becomes partially plugged so that the measurement time delay Is now three minutes. Using your best controller settings of part (d), simulate the closed-loop response for the same set-point change and the new time-delay value. Explain your new simulation results. Does the larger time delay have a major effect on con- trot system performance?
Note: Your solution should include labeled plots for your best responses for parts (c) through (1) and a tabulation of the controller settings.
Process Information
The pilot-scale blending tank has an internal diameter of 2 m and a height of 3 m. Inlet flow rate w1 and inlet composition x2 ate constant. The nominal steady-state operating conditions are as follows:


The overflow line maintains a constant liquid volume in the tank.
Instrumentation: The range for all of the electronic signals is 4 to 20mA.
Current-to-pressure transducer: The 1/P transducer acts as a linear device with negligible dynamics. The output signal changes from 3 to 15 psi when the input signal changes full-scale from 4 to 20mA.
Control valve: The behavior of the control valve can be approximated by a first-order transfer function with a time constant of 5 a (i.e., 0.0833 min). A 1.2-psi change in the signal to the control valve produces a 300 kg/min change in w2.
Composition measurement: The zero and span of the coin- position transmitter for the exit composition are 0 and 0.50 (mass fraction), respectively. A one-minute time delay is associated with the measurement.
Feedback controller: Initially, consider a standard PT controller tuned using the IMC relations in Table 12.1. Justify your choice of tc.

ScholarMatic: Explanation & Answer

Your ready answer from a verified tutor is just a click away for as little as $14.99


  

Click Order Now to get 100% Original Answer Customized to your instructions!

HOME TO CERTIFIED WRITERS

Why Place An Order With Us?

  • Certified Editors
  • 24/7 Customer Support
  • Profesional Research
  • Easy to Use System Interface
  • Student Friendly Pricing

Have a similar question?

PLAGIRAISM FREE PAPERS

All papers we provide are well-researched, properly formatted and cited.

TOP QUALITY

All papers we provide are well-researched, properly formatted and cited.

HIGHLY SECURED

All papers we provide are well-researched, properly formatted and cited.

ScholarMatic: Get Started

Assignment Writing Service

Feel safe and secure when placing an order on our portal!
Fruitful cooperation begins with solid guarantees, and we are professional enough to promise perfect results. Let’s get it started!