Experiment 2: Environmental Variables that Effect
Dissolved Oxygen Levels
In this experiment, you will observe environmental conditions
that affect the levels of dissolved oxygen present in a water
sample. You will use LaMotte Dissolved Oxygen TesTabs® to obtain
qualitative data on the levels present in water samples.
|
Materials 15 cm Aluminum Foil |
Test Tube Rack *You Must Provide |
|

Procedure
Part 1: Effects of Biochemical Oxygen
Demand
Collect a copy of the procedure, two test tubes,
Parafilm® , a permanent marker, aluminum foil, and one
resealable bag.
Venture to a nearby body of water with two test tubes.
Label the test tubes with the body of water’s name/location,
date, and the number 1 or 2.
Carefully approach the water and completely submerge Test Tube 1
with the water source.
Note: Some collectors may wish to wade
into the water to obtain their water sample. As a general Materials
15 cm Aluminum Foil (1) 100 mL Beaker 1 Canning Jar (1) 100 mL
Graduated Cylinder 30 LaMotte Dissolved Oxygen TesTabs® 15 cm
Parafilm® Permanent Marker 1 Resealable Plastic Bag (5) Test Tubes
(Plastic) Test Tube Rack Thermometer 1 Sodium Chloride (Salt)
Packet, NaCl *Hot Water Bath *Water *Outdoor Water Source *You Must
Provide Figure 6: General guidelines for analyzing water samples: 5
– 6 ppm is sufficient for most species; < 3 ppm is stressful for
most species; < 2 ppm is fatal to most species. 405 Ecological
Interactions rule of thumb, water collectors should NOT wade into
flowing water if the water depth (in feet) x the water velocity (in
feet per second) is greater than or equal to 10. If you have any
hesitations regarding water-safety, do NOT enter the water!
Immediately add four LaMotte Dissolved Oxygen TesTabs™ to the
test tube.
Seal the tube with Parafilm®, making sure there are
no air bubbles in the water sample.
Mix the solution by repeatedly inverting the tube until the
tablets have disintegrated (5 – 8 minutes).
Compare the color of the sample to the color chart in Figure 4.
Record the color in Table 2.
Completely submerge Test Tube 2 and seal with ParafilmR while
still under water. You may need to adjust the seal when the tube is
removed from water, but try to minimize the amount of additional
oxygen exposed to the water after the tube is removed from the
water.
Wrap the tube with aluminum foil, and place in a resealable
bag.
Gather your materials and return home. Store Test Tube 2 in a
dark location at room-temperature, for five days.
Repeat Steps 5 – 8.
Note: The difference in the dissolved
oxygen levels between the uncovered tube and the covered tube is
the biochemical oxygen demand of the water sample.
Part 2: Effects of Temperature
Create a hot water bath by performing the following steps:
Determine if you will use a stovetop or microwave to heat the
water. If using a stovetop, obtain a pot. If using
a microwave, obtain a microwave-safe bowl.
Use the 100 mL graduated cylinder to measure and pour
approximately 200 mL of water into the pot or microwave-safe
bowl.
If using a stove, place the pot on the stove and turn the stove
on to medium high. Carefully monitor the water into the pot until
it comes to a boil (approximately 100 °C). Use the thermometer
provided in your lab kit to verify the water temperature. Turn the
stove off when the water begins to boil. Proceed to Step 2.
If using a microwave, place the microwave-safe
bowl in the microwave and heat the water in 30 second increments
until the temperature of the water is approximately 100 °C. Use the
thermometer provided in your lab kit to verify the water
temperature. Proceed to Step 2.
CAUTION: Be
sure to turn the stove off after creating the hot water bath.
Monitor the heating water at all times!
Place a canning jar in the sink and fill with boiling water
until overflowing. Seal the canning jar’s cap on the jar. Allow the
jar to rest for 24 hours.
Fill two test tubes with tap water (do not use the boiling
water) until overflowing. Seal immediately with Fill two test tubes
with tap water (do not use the boiling water) until overflowing.
Seal immediately with Parafilm®.
Place one test tube in the refrigerator and leave one at room
temperature. Allow the test tubes to rest for 24 hours.
Hint: You may wish to use an extra
beaker or the test tube rack to balance the test tubes in an
upright position.
After 24 hours have passed, open the jar immediately and test
the dissolved oxygen concentrations by repeating Part 1: Steps 5 –
8.
Use the thermometer to measure the temperature of the water.
Record your data in Table 1.
Retrieve the test tubes from the refrigerator and the room
temperature environments and repeat Part 1: Steps 5 – 8. Record
your data in Table 1.
Use the thermometer to measure the temperature of the water in
each test tube. Record your data in Table 1.
Part 3: Effects of Salinity
Use the 100 mL graduated cylinder to measure and pour 50 mL tap
water into the 100 mL beaker.
Add one packet of salt to the beaker. Use a stir stick to mix
the solution.
Label a new test tube as “Brine” and fill it with the salt-water
solution until the tube is overflowing.
Test the dissolved oxygen concentration by repeating Part 1:
Steps 5 – 8. Record your data in Table 1.
|
Table 2: Dissolved Oxygen Analysis |
|
|
Biochemical Oxygen Demand Analysis |
ppm |
|
Fresh Water Sample (Test Tube 1) |
|
|
Water Sample after 5 Days (Test Tube 2) |
|
|
Effect of Temperature |
ppm |
|
Boiled (temperature: ) |
|
|
Refrigerator (temperature: ) |
|
|
Room Temperature (temperature: ) |
|
|
Effect of Salinity |
ppm |
|
Brine Solution |
|
About what numbers do you think should go into Table 2?
O ppm 4 ppm 8 ppm Figure 6: General guidelines for analyzing water samples: 5 – 6 ppm is sufficient for most 3 ppm is stressful for most species; < 2 ppm is fatal to most species. species;